<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>auto switching-on Emergency Light | Electronic Schematic Diagram</title>
	<atom:link href="https://electronicscheme.net/tag/auto-switching-on-emergency-light/feed/" rel="self" type="application/rss+xml" />
	<link>https://electronicscheme.net</link>
	<description>Schematic Diagram &#38; PCB Design</description>
	<lastBuildDate>Wed, 09 Sep 2015 00:13:21 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://i0.wp.com/electronicscheme.net/wp-content/uploads/2017/05/cropped-transparent_text_effect.png?fit=32%2C32&#038;ssl=1</url>
	<title>auto switching-on Emergency Light | Electronic Schematic Diagram</title>
	<link>https://electronicscheme.net</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">129969089</site>	<item>
		<title>Automatic Switching-on Emergency Light</title>
		<link>https://electronicscheme.net/automatic-switching-on-emergency-light/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=automatic-switching-on-emergency-light</link>
					<comments>https://electronicscheme.net/automatic-switching-on-emergency-light/#respond</comments>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Thu, 08 Dec 2011 06:49:47 +0000</pubDate>
				<category><![CDATA[Battery Charger]]></category>
		<category><![CDATA[Inverter]]></category>
		<category><![CDATA[LED and Light]]></category>
		<category><![CDATA[auto switching-on Emergency Light]]></category>
		<category><![CDATA[automatic Emergency Light]]></category>
		<category><![CDATA[Battery Charger circuit]]></category>
		<category><![CDATA[emergency light circuit]]></category>
		<category><![CDATA[overcharge protection battery charger]]></category>
		<guid isPermaLink="false">http://electronicscheme.net/?p=1555</guid>

					<description><![CDATA[<p>Automatic Switching-on Emergency Light The schematic diagram shown right here is the automatic switching-on emergency light circuit which is controlled using IC. The most important&#160;[&#8230;]</p>
The post <a href="https://electronicscheme.net/automatic-switching-on-emergency-light/">Automatic Switching-on Emergency Light</a> first appeared on <a href="https://electronicscheme.net">Electronic Schematic Diagram</a>.]]></description>
										<content:encoded><![CDATA[<p>Automatic Switching-on Emergency Light</p>
<p><a href="http://electronicscheme.net/automatic-switching-on-emergency-light.html/automatic-switching-on-emergency-light-circuit-diagram" rel="attachment wp-att-1556"><img data-recalc-dims="1" fetchpriority="high" decoding="async" data-attachment-id="1556" data-permalink="https://electronicscheme.net/automatic-switching-on-emergency-light/automatic-switching-on-emergency-light-circuit-diagram/" data-orig-file="https://i0.wp.com/electronicscheme.net/wp-content/uploads/2011/12/Automatic-Switching-on-Emergency-Light-Circuit-Diagram.jpg?fit=723%2C764&amp;ssl=1" data-orig-size="723,764" data-comments-opened="1" data-image-meta="{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}" data-image-title="Automatic Switching-on Emergency Light Circuit" data-image-description="&lt;p&gt;Automatic Switching-on Emergency Light Circuit.&lt;br /&gt;
When mains is absent, relay RL2 is in deenergised state, feeding battery supply to inverter section via its N/ C contacts and switch S1. The inverter section comprises IC2 (NE555) which is used in stable mode to produce sharp pulses at the rate of 50 Hz for driving the MOSFETs. The output of IC3 is fed to gate of MOSFET (T4) directly while it is applied to MOSFET (T3) gate after inversion by transistor T2. Thus the power amplifier built around MOSFETs T3 and T4 functions in push-pull mode.&lt;/p&gt;
" data-image-caption="" data-large-file="https://i0.wp.com/electronicscheme.net/wp-content/uploads/2011/12/Automatic-Switching-on-Emergency-Light-Circuit-Diagram.jpg?resize=630%2C380&amp;ssl=1" class="size-medium wp-image-1556 aligncenter" title="Automatic Switching-on Emergency Light Circuit Diagram" src="https://i0.wp.com/electronicscheme.net/wp-content/uploads/2011/12/Automatic-Switching-on-Emergency-Light-Circuit-Diagram-283x300.jpg?resize=283%2C300" alt="Automatic Switching-on Emergency Light Circuit Diagram" width="283" height="300" /></a></p>
<p>The schematic diagram shown right here is the automatic switching-on emergency light circuit which is controlled using IC. The most important capabilities of this circuit are: automatic switching-on of the light on main power failure and battery charger with overcharge protection.</p>
<p>When mains electrical power is absent, relay RL2 is in deenergised state, feeding DC source from battery to inverter section via its N/C contacts and switch S1. The inverter section comprises IC2 (NE555) that is applied in stable mode to generate sharp pulses / wave with frequency of 50 Hz to drive the power MOSFETs. The output of IC3 is fed to gate of MOSFET (T4) directly while it is applied to MOSFET (T3) gate just after inversion by transistor T2. Therefore the power amplifier designed close to MOSFETs T3 and T4 functions in push-pull mode.<br />
<span id="more-1555"></span></p>
<p>The output across secondary of transformer X2 can simply drive a 230-volt, 20-watt fluorescent tube. In event light isn&#8217;t needed to become on during mains power failure, then just flip switch S1 to off position.</p>
<p>Battery overcharge preventer circuit is designed close to IC1 (LM308). Its non-inverting pin is held at a reference voltage of about 6.9 volts that is obtained implementing diode D5 (1N4148) and 6.2-volt zener D6. The inverting pin of IC1 is connected to the positive terminal of battery. Thus when mains electric supply is present, IC1 comparator output is high, unless battery voltage exceeds 6.9 volts. So transistor T1 is normally forward biased, which energises relay RL1. Within this state the battery stays on charge via N/O contacts of relay RL1 and current limiting resistor R2. When battery voltage exceeds 6.9 volts (overcharged condition), IC1 output goes low and relay RL1 gets deenergised, and thus stops more charging of battery.</p>
<p>MOSFETs T3 and T4 may be mounted on appropriate heat sinks to prevent overheating on the MOSFETs and keep the MOSFETs in good performance.</p>
<p>This automatic switching-on emergency light circuit taken from EFY magazine. The circuit is already tested and should be working properly. This circuit idea available in PDF document, download from the following link:<br />
<div class='w3eden'><!-- WPDM Link Template: Default Template -->

<div class="link-template-default card mb-2">
    <div class="card-body">
        <div class="media">
            <div class="mr-3 img-48"><img decoding="async" class="wpdm_icon" alt="Icon" src="https://electronicscheme.net/wp-content/plugins/download-manager/assets/file-type-icons/pdf.svg" /></div>
            <div class="media-body">
                <h3 class="package-title"><a href='https://electronicscheme.net/download/automatic-emergency-light-project/'>Automatic Emergency Light Project</a></h3>
                <div class="text-muted text-small"><i class="fas fa-copy"></i> 1 file(s) <i class="fas fa-hdd ml-3"></i> 275.55 KB</div>
            </div>
            <div class="ml-3">
                <a class='wpdm-download-link download-on-click btn btn-primary ' rel='nofollow' href='#' data-downloadurl="https://electronicscheme.net/download/automatic-emergency-light-project/?wpdmdl=3475&refresh=69dbaea41f5711776004772">Download</a>
            </div>
        </div>
    </div>
</div>

</div></p>The post <a href="https://electronicscheme.net/automatic-switching-on-emergency-light/">Automatic Switching-on Emergency Light</a> first appeared on <a href="https://electronicscheme.net">Electronic Schematic Diagram</a>.]]></content:encoded>
					
					<wfw:commentRss>https://electronicscheme.net/automatic-switching-on-emergency-light/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">1555</post-id>	</item>
	</channel>
</rss>
